Jowa Cleantoil 9000 Manual Pdf -

: Installed in the cargo control room to process data and control discharge valves.

: 15 ppm (automatic discharge shutdown).

: Uses light scattering or IR sensors to detect oil concentration (typically 0–1000 ppm).

is an Oil Content Meter (OCM) used within an Oil Discharge Monitoring and Control System (ODMCS) on oil tankers. It is designed to meet MARPOL requirements by monitoring oil content in discharge water. Manual Overview jowa cleantoil 9000 manual pdf

Improper startup is the leading cause of biological system failure on ships. The manual outlines a strict protocol for commissioning or restarting the system after a period of inactivity. Initial Startup Checklist

: Contains the oil content measuring unit, sample pump, and fresh water valve for cleaning. Computer Unit

The CLEANTOIL 9000 functions as an automated supervisor for overboard discharges. It continuously measures the oil content in ballast water and slop tank discharges, calculating the "instantaneous rate of oil discharge" (liters per nautical mile) to ensure it stays within legal limits (typically 30 L/nm). Key Technical Components According to technical documentation found on , the system consists of: Computer Unit: : Installed in the cargo control room to

Review performance testing procedures via the Scribd JOWA 9000 Calibration Guide .

When the system triggers a fault, operators must consult the system's precise diagnostic tables. The manual outlines the following action steps for common failures: JOWA CLEANTOIL 9000 Manual | PDF | Valve | Pump - Scribd

The separator is equipped with an automatic discharge mechanism that expels accumulated sludge and water at set intervals without stopping the machine. is an Oil Content Meter (OCM) used within

| Interval | Task | | :--- | :--- | | | Check gear oil level; Check for vibration/leaks. | | Weekly | Check V-belt tension; Verify operating water pressure. | | Monthly | Check brake function; Inspect inlet/outlet pressure gauges. | | 2,000 Hours | Change gear oil (Use specified EP gear oil). | | 4,000 Hours | Major Service: Dismantle bowl, inspect discs, check sliding bowl bottom seals (O-rings). |

If you need help diagnosing a specific issue with your unit, please let me know the or system behavior you are seeing. I can provide the direct troubleshooting steps from the manual. Share public link

Start the system from the computer unit. Confirm the overboard discharge valve opens only after the system stabilizes (typically about 1 minute after startup). Calibration and Testing

Pin It on Pinterest

Share This