A standard SmarTest test program relies on plain-text configuration files:

The 93k uses an equation-based timing system. Instead of hard-coding values, engineers use variables to define cycle times and edge placements, allowing for easy frequency scaling during characterization.

Contains system power supplies, water cooling heat exchangers, and the primary system controller.

Since Advantest acquired Verigy, the best place to find the most current documentation is on the or within the SmarTest installation directory on the tester itself. Look for PDF versions of: V93000 System User Manual V93000 Hardware Reference SmarTest Test Program Development Guide

Map out the physical channels to your DUT pins. verigy 93k tester manual

Tip from the manual : Always initialize setLevels() before setTimings() in your test method, else you risk undefined pin states.

Performs internal voltage references checking without removing production hardware. Diagnostics Utilities

| Document Name | Content Summary | |---------------|------------------| | | Pin electronics, timing sets, voltage levels | | SmarTest Programming Guide | Test method coding (C++/Python), testflow | | Pattern Compiler Manual | Generating TIL/STIL vectors, timing alignment | | Service & Diagnostics Guide | Calibration procedures, channel failure analysis |

Maintaining the physical integrity and accuracy of an ATE system requires stringent adherence to calibration protocols. System Calibration (System Cal) A standard SmarTest test program relies on plain-text

Sets the DC voltages for input highs/lows ( VIHcap V sub cap I cap H end-sub VILcap V sub cap I cap L end-sub ) and output compare thresholds ( VOHcap V sub cap O cap H end-sub VOLcap V sub cap O cap L end-sub

requires a deep understanding of its core software, (specifically SmarTest 8), which is built on a Linux and Eclipse-based environment.

Follow the scheduled calibration procedures for analog and RF pin cards to maintain test accuracy.

: For specific API verification, highlight the API in the Test Method editor and click Dynamic Help to see relevant info from the TDC. ADVANTEST CORPORATION Key Technical Manuals & Resources System Reference Since Advantest acquired Verigy, the best place to

Designed with water-cooled building blocks.

Dedicated modules for providing precise power to the SoC.

SmarTest (versions 5, 6, 7, and 8) is the operating environment. The manual describes two primary programming models:

For test engineers, a deep understanding of the is not just a suggestion; it is a career necessity. The manual is not a single document but an ecosystem of technical references, programming guides, and diagnostic scripts. This article serves as your roadmap to mastering the 93K’s documentation, from basic architecture to advanced pattern debugging.

A comprehensive internal software check that exercises relays, parametric measurement units (PMUs), and pin channels. Run diagnostics during scheduled down-time to catch degrading hardware components before they impact production line yields.